Our Products

IRIS Addressable Fire Control Panel

IRIS addressable alarm control panel using intelligent analog addressable techniques, it monitors and controls input and output devices, offering the very best in capacity, capability and reliability in fire alarm systems. Furthermore this system can supervise a wide range of smoke, heat and gas detectors, call points, alarm bells, automatic extinguishers, etc., offering an outstanding ability for quick response to dangerous situations.

Features:

* 1 or 2 loop versions as standard.
* 96 zones.
*320 x 240 CSTN graphic display.
* Touch panel.
*Complies with EN54-2/4.
* Real time clock.
* Thermal printer (optional).
* Modem (optional)
* Up to 128 programmable Inputs/outputs.
* Simple Windows graphical configuration utility via Ethernet or USB.
* Comprehensive day/night mode facility.
*Operating Temperature from -5 to +80C- °.
* Repeater option.
* Fully supports System Sensor protocol series 200 and 500.

Fire Control Panel

A fire alarm control panel is a control device that detects, reports and acts on hazardous fires in buildings. This protective system is bound by many different rules and safety regulations before it can be sold. Fire alarm panel repair must be done by certified technicians only. Manual fire detection points such as manual pull stations, smoke detectors and heat detectors in a building are all hooked up to a control panel.

Features:

* One 12V/7Ah battery for stand-by supply;
* Manual trigger of the fire alarm;
* Class change input;
* Abundant LED indications;
* Security key for switching over between access levels 1 and 2;
* Independent Enable/Disable of each zone and sounders;
ABS plastic box;
* Consumption – 50 mA.
* Conventional fire alarm control panel, expandable up to 16 zones;

Flame Detector

The Ultraviolet/ Infrared flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects fires by monitoring in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. It is widely used in several places such as

# Car parking areas, multi-storeyed car parking facilities.
# High ceiling, open spaced buildings such as warehouses.
# Outdoor or semi outdoor areas where winds can prevent
# Smoke from reaching a heat or smoke detectors.Areas where rapidly developing flaming fires can occur, such as storage and transfer areas.

Features:

* Supply voltage U 12-30 V DC
* Sensitivity in accordance with EN 54-10 Class 3 (IR); IR - 800-1000 nm
* Output in alarm state at terminal 1 OC type, through a 500 Ohm resistor
* Operational temperature range -10 / +55°C
* Relative humidity resistance (93 ± 3) % at 40°C
* Dimensions (incl. base) diameter 106 mm, h 48 mm
* Weight (incl. base) 160 g

Heat Detector

A heat detector is a device that detects heat and can be either electrical or mechanical in operation. Rate-of-rise (ROR) heat detectors react to the sudden change or rise in ambient temperature from a normal baseline condition. Any sudden temperature increase that matches the predetermined alarm criteria will cause an alarm. A typical alarm may sound when the rate of temperature rise exceeds 12° to 15°F (6.7° to 8.3°C) per minute.

Features:

* power supply 9-30V.
* EN54 certified.
* Relative humidity resistance (93 ± 3) % at 40°C
* Operational temperature range -10 / +60°C

Smoke Detector

This reflective photoelectric smoke detector, which is small in size utilizes the very latest Optical Chamber technology. It is microprocessor controlled and offers the very best in safety and quality. Once smoke is detected it will send a signal to the main control panel,that will immediately activate an alarm.

Features:

*optical smoke detector.
* EN54 certified.
*power supply 9-30V
* Protected area up to 120 m2 (in accordance to EN54)
* Supply voltage U 12-30 V DC
* Detection method:
Reflective photoelectric sensor
* Excellent stability with high sensitivity

Hooter/Siren

verzent offers a complete range of gas detector product and can respond to dangerous chemicals and poisonous gases. Many times it is required to warn/alert people to a gas leak.so it is necessary to use these type of products.

Features:

* ABS Plastic Bobby
* 12VDC, 500MA
* Sound Output 110db
* Size 100*70

Features:

* For indoor piezo siren, plastic box, 105 dB/1m, with red flash. For outdoor siren volume will be 96db
* Speaker piezo
* Base frequency 3.2 – 3.8 kHz(outdoor),3.1 – 3.7 kHz(indoor)
* Modulating frequency 3 Hz
* Box plastic
* Consumption 80 mA

Call Point

Used as manual alarm at the fire site when the person confirms that there is a fire.

Features:

* Operating Temperature: -10?~+50?
* Operating Humidity : 0 to 95 RH, no condensation or icing
* Operating Voltage: DC12~ 24V
* Operating Current: 1 mA
* ?Have one N/C (normal close) relay output and one * N/O (normal open) relay output
* Weight: 200gn

 